DS Series

decontactor dsn

Choose DS Series for its...

  • Switch & horsepower ratings
  • Higher amperage range (20-200A)
  • Poly or metal casings (some sizes)
  • Common Applications

  • Most industrial applications
  • High hp motor applications
DS20 DS30 DS60 DS100C DS100 DS200
Voltage Voltage Voltage Voltage Voltage Voltage
600 VAC, 250 VDC 600 VAC, 250 VDC 600 VAC, 250 VDC 600 VAC, 250 VDC 600 VAC, 250 VDC 480 VAC
Switch Ratings (AC Only) Switch Ratings (AC Only) Switch Ratings (AC Only) Switch Ratings (AC Only) Switch Ratings (AC Only) Switch Ratings (AC Only)
Branch Circuit & Motor Circuit Disconnect Switching Branch Circuit & Motor Circuit Disconnect Switching Branch Circuit & Motor Circuit Disconnect Switching Branch Circuit & Motor Circuit Disconnect Switching Branch Circuit Disconnect Switching Branch Circuit Disconnect Switching
Horsepower Ratings Horsepower Ratings Horsepower Ratings Horsepower Ratings
120V 1Ø 3/4 hp 120V 1Ø 1 1/2 hp 120V 1Ø 2 hp 120V 1Ø 3 hp
240V 1Ø 3 hp 240V 1Ø 3 hp 240V 1Ø 5 hp
208V 3Ø 3 hp 208V 3Ø 5 hp 208V 3Ø 7 1/2 hp 208V 3Ø 10 hp
240V 3Ø 5 hp 240V 3Ø 5 hp 240V 3Ø 10 hp 240V 3Ø 10 hp
480V 3Ø 7 1/2 hp 480V 3Ø 15 hp 480V 3Ø 20 hp 480V 3Ø 25 hp
600V 3Ø 10 hp 600V 3Ø 15 hp 600V 3Ø 25 hp 600V 3Ø 25 hp
Short Circuit Rating Short Circuit Rating Short Circuit Rating Short Circuit Rating Short Circuit Rating Short Circuit Rating
100kA Close & Withstand Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp rating. 100kA Close & Withstand Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp rating. 100kA Close & Withstand Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp rating. 100kA Close & Withstand Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp rating. 65kA Close & Withstand Testing was performed with RK5 time delay fuses sized at 100% of the devices rated ampacity. 65kA Close & Withstand Testing was performed with RK5 time delay fuses sized at 100% of the devices rated ampacity.
Environmental Ratings Environmental Ratings Environmental Ratings Environmental Ratings Environmental Ratings Environmental Ratings
Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed. Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed. Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed. Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed. Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed. Type 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed.

All DS Models are listed as follows:


Category UL CSA IEC
Plugs and Receptacles UL 1682 C22.2 No. 182.1 60309-1
Branch Circuit Disconnect Switching (AC Only) UL Subject 2682 (Performance tests from UL 98) UL Subject 2682 60947-3, AC22, AC23
Motor Circuit Disconnect Switching (AC Only) UL Subject 2682 (Performance tests from UL 98) UL Subject 2682

CE marked DS models are available. Contact MELTRIC.

Lockout-Tagout

Maximum Safety

Lockout-Tagout

Cost Savings

Lockout-Tagout

Reliability & Durability

Lockout-Tagout

Simplify NFPA 70E Compliance

Lockout-Tagout

Quick Equipment Change-outs

Lockout-Tagout

Meet "line of sight" disconnect